Dynamic Pressure Measurement (e.g., shock waves, high-frequency vibration)?
Type?: Piezoelectric pressure sensor
Advantages?: Nanosecond-level dynamic response, suitable for high-frequency pressure changes (e.g., engine knock detection, aerodynamic shockwave analysis).
Technical Notes?: Uses quartz or piezoelectric ceramic materials; static accuracy ±0.1% FS, but charge leakage may cause zero drift.
Static/Low-Frequency Pressure (e.g., hydraulic systems, industrial pipelines)?
Type?: Strain gauge pressure sensor
Advantages?: High static accuracy (±0.03% FS), stable measurement via strain tube/membrane structures, compliant with JB/T 5493-1991 standard.
Applications?: Hydraulic pump control, tank level monitoring, pressure range 0-2000 mbar.
Corrosive Media/Harsh Environments (e.g., chemical, deep-sea)?
Type?: Absolute pressure sensor (sealed vacuum reference)
Advantages?: Absolute vacuum reference, corrosion-resistant materials (e.g., 316 stainless steel, Hastelloy), suitable for deep-sea (10MPa) or chemical processes.
Note?: Choose models with temperature compensation for non-corrosive gases.
Consumer Electronics/Medical Devices (e.g., wearables, blood pressure monitors)?
Type?: MEMS barometric sensor
Advantages?: Miniaturized, low-power, integrated temperature compensation, altitude accuracy ±1 meter.
Applications?: Smartphone barometers, medical ventilator pressure monitoring.
Key Parameter Comparison?
Type Dynamic Response Static Accuracy Environmental Adaptability Typical Error
Piezoelectric Nanosecond ±0.1% FS Charge leakage sensitive Significant thermal drift
Strain gauge kHz-level ±0.03% FS Vibration-resistant Low mechanical hysteresis
MEMS Millisecond ±0.5% FS Needs temperature compensation Weather-dependent
Special Conditions?
High-temperature?: Prioritize thin-film sensors to reduce thermal drift (<1% FS/℃).
High-vibration?: Use compact unamplified sensors with EMI shielding.
Note: Contact Niko staff for specific technical consultation.