Technical Specification of NKGF Series Gear Flow Sensor?
Model?: NKGF Series
Description?:
The NKGF gear flow sensor utilizes a dual-gear mechanism to calculate fluid volume via high-precision displacement measurement, designed for continuous or intermittent monitoring of liquid flow rate or instantaneous flow in pipelines.
Key Features?:
Dual-output (analog & switching signals)
Configurable PNP/NPN output
LED display
High pressure resistance (1.0–40MPa) and extreme temperature tolerance (-196°C to 200°C)
Compatible with viscous media (up to 10,000 cP)
Wide measuring range (1:100 ratio) and high repeatability (0.1% F.S)
Corrosion-resistant (acids/alkalis)
Applications?:
Industries?: Automotive, aviation, mining, power, chemical, pharmaceutical, food, coatings, petroleum, environmental, printing.
Media?: Additives, fuels, flotation agents, corrosion inhibitors, catalysts, emulsifiers, oils, adhesives, solvents, inks, pesticides, high-viscosity fluids (e.g., heavy oil, PVA, resins).
Technical Parameters?:
Flow Range?: 0.005–330 L/min (customizable)
Output?: Pulse, 4–20mA, PNP/NPN
Accuracy?: ±0.5% F.S
Power Supply?: 16–30V DC
Pressure Rating?: Aluminum (100 bar), Stainless steel (400 bar), PP (50 bar)
Materials?: Housing (aluminum/SS/PP), Display (SS)
Installation & Maintenance?:
Ensure fluid cleanliness (no fibers/particulates).
Valve Operation?:
For non-bypass systems: Gradually open upstream valve to moderate flow, then adjust downstream valve after 10-min low-flow operation.
For bypass systems: Activate bypass first, then follow similar sequential valve adjustment.
Use "two-stage opening/closing" for large-diameter sensors to prevent hydraulic shock.
Routine Checks?: Monitor gear rotation; abnormal noise warrants immediate inspection.
Maintenance Cycle?: Quarterly. Clean components without damaging internal parts.
Storage?: Purge residual fluid, cap ports, and store in dry conditions.
Filter Maintenance?: Clean periodically and protect when unused.
Note?: Specifications subject to customization based on user requirements and operational conditions.
(Translation adheres to technical accuracy, omits promotional content, and retains all functional details from the source material.)
Contact:Mr.Tu
Tel:18001874240
Email:noike009@foxmail.com